Reagents

Clear all
  • Blood Glucose Monitoring x close icon
  • ELISA Autoimmune x close icon
  • LAMP x close icon
  • Rapid Screening Tests x close icon

89 Items are shown

Quantitative determination of IgG antibodies to anti-mitochondrial antigen M2.
Qualitative determination of anti-nuclear IgG antibodies. Internal function and cut-off control
Quantitative determination of IgG / IgA / IgM antibodies to annexin V. Calibration:6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 25 U/ml
Quantitative determination of IgG autoantibodies to complement C1q. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 20 U/ml
Latex slide test for non-diluted serum
Determination of antibodies to cardiolipin
Quantitative / qualitative determination of IgG antibodies to cyclic citrullinated peptide. Calibration: 25 / 50 / 200 / 800 / 1600 U/ml Cut-off: 25 U/ml
Immunochromatographic rapid test for Chlamydia trachomatis LPS antigen
Quantitative determination of C3d containing circulating immune complexes of IgG
Quantitative determination of complement activity.
Latex slide test for non-diluted serum.
Quantitative determination of IgG antibodies to double-stranded DNA. Calibration: Quantitative, 12.5 / 25 / 50 / 100 / 200 IU/ml Cut-off: 25 U/ml
Simultaneously qualitative determination of IgG antibodies to extractable nuclear antigens. Cut-off control and cut-off calibrator
Agglutination slide and tube test for qualitative and semi-quantitative determination of antibodies against Salmonella typhi H, Salmonella typhi O, Salmonella paratyphi AH, Salmonella paratyphi AO, Salmonella paratyphi BH, Salmonella paratyphi BO, Salmonella paratyphi CH, Salmonella paratyphi CO
Quantitative determination of IgG antibodies to glomerular basement membrane. Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Quantitative determination of antibodies to deamidated Gliadin.
Glucose (GLUC) measurements are used for diagnosis and therapy control of carbohydrate metabolism disorders. Elevated glucose values (hyperglycemia) are observed in the following discorders: diabetes mellitus, gestational diabetes and Addison's disease. Decreased glucose values (hypoglycemia) are observed in neonatal hypoglycemia, congenital enzyme defects, Reye's syndrome, hepatic dysfunction, insulinomas, insulin antibodies, alcohol ingestion, neoplasms, sepsis and chronic renal failure.
Immunochromatographic rapid test for H. pylori IgG, IgM, IgA antibodies
Immunochromatographic 1-step test for Hepatitis B surface antigen (HBsAg). Please note: Hexagon HBsAG currently without CE mark
Immunochromatographic rapid test for antibodies to HIV-1 and -2
Hemagglutination slide test for heterophilic antibodies associated with infectious mononucleosis.
Quantitative / qualitative determination of IgG antibodies to Jo-1. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative determination of IgG antibodies to liver-kidney microsomal antigen 1.
Qualitative test for differentiation of Plasmodium vivax parasites. Storage and shipment at 2...30°C
Quantitative determination of IgG antibodies to myeloperoxidase. Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Immunochromatographic rapid test for the qualitative detection of faecal occult blood in human stool
Lyophilizied human serum-based matrix containing multi-parameter analytes for HumaCLIA SR assays To be used with : TSH, fT3, fT4, T3, T4, anti-TG, anti-TPO, TG, AFP, CEA,CA-125, CA 19-9,CA 15-3, FSH, LH, HCG, Progesterone, Testosterone, Prolactin, Estradiol (E2), DHEA-S, PSA*, fPSA*, 25-OH Vitamin D, PTH, Folate, Vitamin B12, Cortisol, Troponin I, CK-MB, Myoglobin *No CE – only for use outside Europe
Quantitative determination of IgG / IgA / IgM antibodies to phosphatidylethanolamine. Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15 U/ml
Determination of antibodies to phosphatidylserine
Quantitative determination of IgG / IgM antibodies to phospholipids. Calibration: 6 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15-25 U/ml
Quantitative determination of IgG antibodies to proteinase 3. Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
HEXAGON and HumaPreg pregnancy tests feature a sensitivity of at least 25 IU/l hCG and are available in different formats: single-sealed cassette and strip tests.
Immunochromatographic rapid test for prostate specific antigen (PSA)
Quantitative determination of IgG / IgA / IgM antibodies to prothrombin. Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 30 U/ml
Quantitative determination of IgG antibodies to RA33. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative determination of IgM antibodies to rheumatoid factor. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 15 IU/ml
Qualitative determination of antibodies to salmonella.
Quantitative / qualitative determination of IgG antibodies to Scl70. Calibration: 12.5/25/50/100/200 U/ml Cut-off: 25 U/ml
Latex slide test for serum.
Quantitative / qualitative determination of IgG antibodies to SmD. Calibration: 12.5 /25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Determination of antibodies to ß2-Glycoprotein 1
Quantitative / qualitative determination of IgG antibodies to SS-A/Ro. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative / qualitative determination of IgG antibodies to SS-B/La. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Rapid tests for the detection of syphilis. Hexagon Syphilis: Immunochromatographic rapid test Syphilis RPR: Rapid plasma reagin charcoal enhanced flocculation test Syphilis TPHA liquid: Hemagglutination test
Determination of antibodies to thyroglobulin
Quantitative determination of antibodies to thyroperoxidase.
Quantitative determination of Thyrotropin.
Test for the triage of patients suspected for myocardial infarction in locations without access to particle-based chemiluminescent Troponin immunoassays. Immunochromatographic 1-step test for cardiac troponin I (cTnI). Detection limit: 0.5 ng/ml.
Quantitative determination of antibodies to tissue transglutaminase.
Qualitative test for the detection of bacteria belonging to Mycobacterium Tuberculosis Complex (MTBC). Storage and shipment at 2...30°C
Quantitative / qualitative determination of IgG antibodies to U1-snRNP. Calibration: 12.5/25/50/100/200 U/ml Cut-off: 25 U/ml

Need help finding instruments?

We will gladly assist you in making the right decision to achieve your business goals

message question circle icon Get a consultation
Need help finding instruments?
Loading…
Loading the web debug toolbar…