Reagents

Clear all
  • Blood Glucose Monitoring x close icon
  • ELISA Autoimmune x close icon
  • LAMP x close icon
  • Multi Parameter Monitoring x close icon

58 Items are shown

Quantitative determination of IgG antibodies to anti-mitochondrial antigen M2.
Qualitative determination of anti-nuclear IgG antibodies. Internal function and cut-off control
Quantitative determination of IgG / IgA / IgM antibodies to annexin V. Calibration:6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 25 U/ml
Quantitative determination of IgG autoantibodies to complement C1q. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 20 U/ml
Determination of antibodies to cardiolipin
Quantitative / qualitative determination of IgG antibodies to cyclic citrullinated peptide. Calibration: 25 / 50 / 200 / 800 / 1600 U/ml Cut-off: 25 U/ml
Total cholesterol (CHOL) measurements are used for diagnosis and therapy control of atherosclerotic coronary vascular disease and metabolic disorders such as dyslipidemia and liver diseases. The concentration of total cholesterol in serum or plasma is influenced by different factors like age, sex, diet and physical activity. Colorimetric enzymatic test for the quantitative determination of total cholesterol in human serum and plasma.
Quantitative determination of C3d containing circulating immune complexes of IgG
Quantitative determination of complement activity.
Quantitative determination of IgG antibodies to double-stranded DNA. Calibration: Quantitative, 12.5 / 25 / 50 / 100 / 200 IU/ml Cut-off: 25 U/ml
Simultaneously qualitative determination of IgG antibodies to extractable nuclear antigens. Cut-off control and cut-off calibrator
Quantitative determination of IgG antibodies to glomerular basement membrane. Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Quantitative determination of antibodies to deamidated Gliadin.
Glucose (GLUC) measurements are used for diagnosis and therapy control of carbohydrate metabolism disorders. Elevated glucose values (hyperglycemia) are observed in the following discorders: diabetes mellitus, gestational diabetes and Addison's disease. Decreased glucose values (hypoglycemia) are observed in neonatal hypoglycemia, congenital enzyme defects, Reye's syndrome, hepatic dysfunction, insulinomas, insulin antibodies, alcohol ingestion, neoplasms, sepsis and chronic renal failure.
Quantitative / qualitative determination of IgG antibodies to Jo-1. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative determination of IgG antibodies to liver-kidney microsomal antigen 1.
Qualitative test for differentiation of Plasmodium vivax parasites. Storage and shipment at 2...30°C
Quantitative determination of IgG antibodies to myeloperoxidase. Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Lyophilizied human serum-based matrix containing multi-parameter analytes for HumaCLIA SR assays To be used with : TSH, fT3, fT4, T3, T4, anti-TG, anti-TPO, TG, AFP, CEA,CA-125, CA 19-9,CA 15-3, FSH, LH, HCG, Progesterone, Testosterone, Prolactin, Estradiol (E2), DHEA-S, PSA*, fPSA*, 25-OH Vitamin D, PTH, Folate, Vitamin B12, Cortisol, Troponin I, CK-MB, Myoglobin *No CE – only for use outside Europe
Quantitative determination of IgG / IgA / IgM antibodies to phosphatidylethanolamine. Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15 U/ml
Determination of antibodies to phosphatidylserine
Quantitative determination of IgG / IgM antibodies to phospholipids. Calibration: 6 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 15-25 U/ml
Quantitative determination of IgG antibodies to proteinase 3. Calibration: 2.5 / 7.4 / 22.2 / 66.7 / 200 U/ml Cut-off: 10 U/ml
Quantitative determination of IgG / IgA / IgM antibodies to prothrombin. Calibration: 6.25 / 12.5 / 25 / 50 / 100 U/ml Cut-off: 30 U/ml
Quantitative determination of IgG antibodies to RA33. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative determination of IgM antibodies to rheumatoid factor. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 15 IU/ml
Qualitative determination of antibodies to salmonella.
Quantitative / qualitative determination of IgG antibodies to Scl70. Calibration: 12.5/25/50/100/200 U/ml Cut-off: 25 U/ml
Quantitative / qualitative determination of IgG antibodies to SmD. Calibration: 12.5 /25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Determination of antibodies to ß2-Glycoprotein 1
Quantitative / qualitative determination of IgG antibodies to SS-A/Ro. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Quantitative / qualitative determination of IgG antibodies to SS-B/La. Calibration: 12.5 / 25 / 50 / 100 / 200 U/ml Cut-off: 25 U/ml
Determination of antibodies to thyroglobulin
Quantitative determination of antibodies to thyroperoxidase.
Quantitative determination of Thyrotropin.
Quantitative determination of antibodies to tissue transglutaminase.
Qualitative test for the detection of bacteria belonging to Mycobacterium Tuberculosis Complex (MTBC). Storage and shipment at 2...30°C
Quantitative / qualitative determination of IgG antibodies to U1-snRNP. Calibration: 12.5/25/50/100/200 U/ml Cut-off: 25 U/ml
Uric acid measurements are used in the diagnosis and therapy control of numerous renal and metabolic disorders, including chronic kidney disease, kidney stones, renal failure, gout, hyperlipidemia, leukemia, psoriasis, starvation or other wasting conditions and of patients receiving cytotoxic drugs or cyclosporine therapy in transplant recipients. Enzymatic colorimetric test with or without ascorbate oxidase for the quantitative determination of uric acid in human serum, plasma and urine.

Need help finding instruments?

We will gladly assist you in making the right decision to achieve your business goals

message question circle icon Get a consultation
Need help finding instruments?
Loading…
Loading the web debug toolbar…